The Qubit 4 Flurometer is the latest version of the popular Qubit fluorometer designed to accurately measure DNA, RNA, and protein quantity, and now also RNA integrity and quality, using the highly sensitive Qubit assays. The Qubit 4 Fluorometer was re-engineered to run the Qubit RNA IQ (integrity & quality) assay. The Qubit 4 Fluorometer and RNA IQ Assay Kit work together to accurately distinguish intact from degraded RNA in just two easy steps.

For all Qubit assays, the concentration or quality of the target molecule in the sample is reported by a fluorescent dye that emits a signal only when bound to the target, which minimizes the effects of contaminants on the result. The easy-to-use touch-screen menus make it easy to select and run the assays you need, with results displayed in just a few seconds.

Key features of the Qubit 4 Fluorometer include:
• Fast and highly accurate quantitation of DNA, RNA, and protein in less than three seconds per sample
• Measures intact RNA in less than 5 seconds per sample
• High levels of accuracy using only 1–20 μL of sample, even with very dilute samples
• On-board Reagent Calculator quickly generates Qubit working solution preparation instructions
• Stores results from up to 1000 samples
• Large 5.7-inch, state-of-the-art color touch screen for easy workflow navigation
• Graphical display indicates when samples are in the extended range or out of range
• Small footprint saves space on your bench
• Exports data to a USB drive or directly to your computer via a USB cable
• Ability to personalize your Qubit fluorometer with the assays you run most, add new assays, or even create your own assays with the MyQubit software and web tool
• Language of your choice including English, French, Spanish, Italian, German, simplified Chinese, and Japanese

The Qubit 4 Flurometer can also be used to directly measure the fluorescence of samples using Fluorometer mode. Additionally, Ion Sphere Particle quality can be evaluated on the Qubit 4 Fluorometer using the Ion Sphere Quality Control Kit prior to performing a sequencing run on the Ion PGM sequencer.

Enables more accurate results than with UV absorbance at low concentrations
The Qubit 4 Fluorometer is far more sensitive than UV absorbance, which measures anything absorbing at 260 nm, including DNA, RNA, protein, free nucleotides, or excess salts. Moreover, UV spectrophotometry is often not sensitive enough to accurately measure low concentrations of DNA and RNA. With the Qubit fluorometer, your research is enhanced by more accurate measurements because the dyes in the Qubit assay kits fluoresce only when bound to the selected molecule (DNA, RNA or protein) in your sample. This allows you to avoid repeating work due to inaccurate measurements.

Fast, simple, and accurate measurement of RNA quality
The Qubit RNA IQ assay provides a fast, simple method to check whether an RNA sample has degraded. The assay utilizes two unique dyes: one that binds to large, intact RNA, and another that selectively binds to small, degraded RNA. Together they enable you to quickly assess the quality and integrity of an RNA sample. To use, simply add your samples to the RNA IQ working solution, then measure on the Qubit 4 Fluorometer.

Save samples and bench space
The thoughtfully designed Qubit 4 Fluorometer requires samples of only 1–20 µL. It is intended for use at room temperature and occupies only a small amount of bench space. The Qubit 4 Fluorometer features advanced optics and data analysis algorithms, and comes equipped with a USB thumb drive and cable for data transfer to Excel™ software and for software downloads, as well as a universal power supply, four plug adapters, and electromagnetic CE certification.

Single sample measurements are a breeze
This user-friendly fluorometer is combined with quick and simple assay procedures. Calculations and settings are automatically performed by the instrument. The Qubit assays for use with the Qubit 4 Fluorometer are all performed using the same general protocol, which uses a simple mix-and-read format with incubation times of only two minutes for the DNA and RNA assays. 500 ?L thin-walled PCR tubes (Cat. No. Q32856) are required.

System specifications include:

Instrument dimensions: 5.4"(w) x 10" (l) x 2.2" (h) (13.6 cm x 25 cm x 5.5 cm)
Weight: 743 g
Dynamic range: 5 orders of magnitude
Processing time: ≤seconds/sample
Light sources: blue LED (max ~470 nm), red LED (max ~635 nm)
Excitation filters: blue (430–495 nm), red (600–645 nm)
Emission filters: green (510–580 nm), red (665–720 nm)
Detectors: photodiodes, measurement capability from 300–1,000 nm
Warm-up time: <35 seconds
USB thumb drive: 4 GB

上海旦鼎國際貿易有限公司

上海旦鼎國際貿易有限公司

地址:上海市金山區楓涇鎮環東一路65弄3號2994室

主營產品:真空泵,離心機,液氮罐,制冰機,*聲波清洗機,食品安全檢測儀,磁力攪拌器,旋轉蒸發儀,移液器

©2019 版權所有:上海旦鼎國際貿易有限公司  備案號:滬ICP備10210192號-3  總訪問量:1218476  站點地圖  技術支持:化工儀器網  管理登陸

主站蜘蛛池模板: 亚洲中文字幕久爱亚洲伊人| 性饥渴少妇av无码毛片| 国产熟女乱子视频正在播放| 人妻av久久一区波多野结衣| 日本精品无码一区二区三区久久久| 自拍亚洲一区欧美另类| 国产精品青草久久久久福利99| 亚洲另类欧美综合久久图片区| 午夜免费啪视频| 午夜片神马影院福利| 在线观看无码不卡av| 在厨房被c到高潮a毛片奶水| 情侣做性视频在线播放| 欧美一区二区三区成人久久片| 日本丰满熟妇videossex一| 国产69精品久久久久久久| 狠狠躁夜夜人人爽天96| 一本一本久久aa综合精品| 少妇人妻无码专区在线视频| 国产成人精品怡红院在线观看| 一区二区 在线 | 中国| 亚洲欧洲成人精品av97| 国内精品久久人妻互换| 伊人精品一本久久综合| 精品国产福利一区二区三区| 欧美人与性动交ccoo| 色综合久久精品亚洲国产| 四虎永久在线精品免费网址| 国产成人无码免费视频在线 | 日韩中文高清在线专区| 波多野结av在线无码中文| 色婷婷六月亚洲婷婷丁香| 国产色综合天天综合网| 国产亚洲精品福利视频在线观看| 国产亚洲成av人片在线观看| 无码伊人66久久大杳蕉网站谷歌| 24小时日本在线www免费的| 亚洲一区二区三区自拍天堂| 护士奶头又白又大又好摸视频| 国产剧情av麻豆香蕉精品| 成人女人看片免费视频放人|